Portable Radiation Monitoring Products
Products
News
The H2LPDU-G local processing & display unit can be used for the conversion and processing of on site radiation detection signals, measurement display, and remote transmission of measurement information in the radiation monitoring system.
Keywords: Portable Radiation Monitoring Productsoftheanddisplay
The Z3GRM08 γ dose rate monitor can continuously monitor the γ radiation dose rate around detector, especially for γ radiation dose rates close to or below the environmental background.
The Z3DCZT01 quick-deployed CZT spectrometer is a kind of quick-deployed spectrometer detector based on CZT semiconductor, with the characteristics of small size, high integration and excellent energy resolution.
Keywords: Portable Radiation Monitoring Productsoftheanddisplayquick deployed spectrometer system
The Z3SGM01-S unattended environment γ Energy spectral monitoring system is mainly used for detecting the low-level artificial radiation, online spectral analysis, and automatic nuclide identification quickly.
The Z3SGM01 regional γ spectrometer is mainly used for detecting the low-level artificial radiation, online spectral analysis, and automatic nuclide identification quickly.
The Z3HNRM01 regional neutron monitor can monitor the neutron dose equivalent rate in a designated area in real time, and transmit the measured data to the upper computer in real time through RS485 or network port.
The Z3SGM01-M quick-deployed environment γ Energy spectral monitoring system is mainly used for detecting the low-level artificial radiation, online spectral analysis, and automatic nuclide identification quickly.
The Z3WGRM01 wide-range regional γ monitor (POE) can monitor X/γ dose rate with a wide range using two energy compensation GM tubes with different sensitivities.
The Z3RAU01 regional monitoring alarm is used for reading the power supply and measurement data of on-site detection devices in the radiation monitoring system; giving out sound and light alarms based on the obtained data, and uploading them to the host in the upstream network of the regional monitoring system for summary.
The Z2LDU01 local display unit is used for the conversion and processing of on-site radiation detection signals, measurement display, and remote transmission of measurement information in the radiation monitoring system.
The Z3NGRM01M mobile regional neutron γ monitor is composed of a local display unit, an area neutron monitor, and a highly sensitive regional γ monitor. It can monitor the neutron dose equivalent rate and γ dose rate in designated areas through movement, and directly display the measured data on the local display unit screen.